Used – Good CAREFUSION Infant Flow Sipap

550,00 

1 in stock

Description

CAREFUSION Infant Flow SiPAP

Infant ICU Ventilator

Good working condition

With its roling stand and gas hoses

Several units available

FEATURES:

The CareFusion Infant Flow SiPAP is a non-invasive neonatal respiratory support system designed for premature and full-term infants with respiratory distress, commonly used in NICU environments. It delivers CPAP-based ventilation and synchronized pressure support through a nasal interface.

Ventilation Modes

  • nCPAP (Nasal Continuous Positive Airway Pressure) – delivers continuous positive airway pressure to keep alveoli open.
  • BiPhasic mode – alternates between two CPAP pressure levels to assist breathing and improve lung recruitment.
  • BiPhasic Triggered (BiPhasic tr) – patient-triggered pressure support with apnea backup breaths (on Comprehensive models).

Respiratory Technology

  • Variable flow technology for stable airway pressure and reduced work of breathing.
  • Infant Flow generator system that maintains consistent CPAP even with leaks around the nasal interface.
  • Designed specifically for neonates and premature infants requiring gentle respiratory support.

Adjustable Clinical Parameters

  • FiO₂: adjustable from 21% to 100%.
  • CPAP pressure: typically 0–20 cmH₂O range.
  • Breath rate and inspiratory time controls for BiPhasic modes.
  • Adjustable I:E ratio, T-High, and rate settings.

Monitoring & Safety

  • Integrated monitoring of:
    • airway pressure
    • oxygen concentration
    • respiratory rate
    • spontaneous breathing rate
  • Comprehensive alarm system, including:
    • high/low airway pressure
    • high/low FiO₂
    • apnea or low breath rate
    • gas supply failure
    • battery status.

Interface & Usability

  • Touch-screen LCD display with pressure-time waveform graphics.
  • User-friendly controls for quick adjustment in NICU settings.
  • Compatible with nasal prongs or nasal masks.

System & Connectivity

  • RS-232 port for connection to patient monitoring systems or EMR.
  • Up to 2 hours internal battery backup for transport within the hospital.
  • Portable driver unit (~8.8 kg).

Clinical Benefits

  • Helps reduce the need for invasive mechanical ventilation.
  • Supports lung development in premature infants.
  • Used for conditions such as apnea of prematurity, neonatal respiratory distress, or post-extubation support.

Typical applications:

  • NICU respiratory support
  • Post-extubation support
  • Apnea of prematurity treatment